000071037 001__ 71037
000071037 005__ 20180924094516.0
000071037 0247_ $$2doi$$a10.1016/j.aprim.2014.07.001
000071037 0248_ $$2sideral$$a90385
000071037 037__ $$aART-2015-90385
000071037 041__ $$aspa
000071037 100__ $$aGili, M.
000071037 245__ $$aValidación de la versión española de la escala Screening for Somatoform Symptoms-2 para la evaluación de síntomas somáticos en Atención Primaria
000071037 260__ $$c2015
000071037 5060_ $$aAccess copy available to the general public$$fUnrestricted
000071037 5203_ $$aObjetivo
Estudiar la validez diagnóstica y aportar los valores de sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo de la versión española de la escala Screening for Somatoform Symptoms-2 (SOMS-2) en una muestra de pacientes de AP.
Diseño
Estudio de validación.
Emplazamiento
Centros de salud de AP de Aragón y Baleares.
Participantes
Ciento nueve pacientes somatizadores prodecedentes de un ensayo clínico previo y 56 pacientes no somatizadores incluidos para la validación de la escala.
Mediciones principales
Sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y a de Cronbach.
Resultados
De un total de 165 sujetos, el 75% fueron mujeres y el 60% presentó trastorno de somatización y/o trastorno de ansiedad o depresivo. La SOMS-2 de 53 ítems y con un punto de corte de 4 presentó una sensibilidad del 97%, una especificidad del 68%, un valor predictivo positivo del 85%, un valor predictivo negativo del 92% y una alta consistencia interna (a de Cronbach = 0,926).
Conclusiones
La versión española de la SOMS-2 constituye un instrumento de cribado eficaz, útil y de fácil administración para la evaluación de los trastornos somatomorfos en AP. Los resultados de sensibilidad, especificidad y consistencia interna son similares a los de estudios previos de validación de la SOMS-2 en otras lenguas europeas.

Objective
To study the diagnostic validity and to provide the sensitivity, specificity, positive predictive value and negative predictive value of the Spanish version of the Screening for Somatoform Symptoms-2 (SOMS-2) scale in a PC population sample.
Design
Validation study.
Setting
PC centres in Aragon and Balearic Islands, Spain.
Participants
A sample of 109 patients from a clinical trial with somatoform disorders and 56 patients without somatoform disorder were included for the scale validation.
Main outcome measures
Sensitivity, specificity, positive predictive value, negative predictive value and Cronbach's a coefficient.
Results
Of the total sample of 165 subjects, 75% were women and 60% had a diagnosis of somatization disorder and/or anxiety or depressive disorder. The 53-item version of the SOMS-2 with a cut-off point of 4 showed a sensitivity of 97%, a specificity of 68%, a positive predictive value of 85%, a negative predictive value of 92%, and high internal consistency (Cronbach a = 0.926).
Conclusions
The Spanish version of the SOMS-2 seems to be a reliable screening tool, easy to complete and useful for the assessment of somatoform disorders in PC settings. The results for specificity, sensitivity, and internal consistency are similar to previous studies in other European languages.
000071037 536__ $$9info:eu-repo/grantAgreement/ES/ISCIII/FIS/PI05-1886
000071037 540__ $$9info:eu-repo/semantics/openAccess$$aby-nc-nd$$uhttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
000071037 590__ $$a1.098$$b2015
000071037 591__ $$aMEDICINE, GENERAL & INTERNAL$$b83 / 155 = 0.535$$c2015$$dQ3$$eT2
000071037 591__ $$aPRIMARY HEALTH CARE$$b15 / 20 = 0.75$$c2015$$dQ3$$eT3
000071037 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000071037 700__ $$aBauzá, N.
000071037 700__ $$aVives, M.
000071037 700__ $$aMoreno, S.
000071037 700__ $$0(orcid)0000-0002-5494-6550$$aMagallón, R.$$uUniversidad de Zaragoza
000071037 700__ $$aRoca, M.
000071037 7102_ $$11007$$2610$$aUniversidad de Zaragoza$$bDpto. Medicina, Psiqu. y Derm.$$cArea Medicina
000071037 773__ $$g47, 5 (2015), 273-278$$pAten. prim.$$tAtencion Primaria$$x0212-6567
000071037 8564_ $$s246414$$uhttps://zaguan.unizar.es/record/71037/files/texto_completo.pdf$$yVersión publicada
000071037 8564_ $$s76372$$uhttps://zaguan.unizar.es/record/71037/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000071037 909CO $$ooai:zaguan.unizar.es:71037$$particulos$$pdriver
000071037 951__ $$a2018-09-24-09:37:16
000071037 980__ $$aARTICLE