000070325 001__ 70325
000070325 005__ 20200609132532.0
000070325 0247_ $$2doi$$a10.1155/2018/4032043
000070325 0248_ $$2sideral$$a105856
000070325 037__ $$aART-2018-105856
000070325 041__ $$aeng
000070325 100__ $$0(orcid)0000-0002-0227-1934$$aGarcia-Ramos, F.J.$$uUniversidad de Zaragoza
000070325 245__ $$aApplicability of Ammonia Sensors for Controlling Environmental Parameters in Accommodations for Lamb Fattening
000070325 260__ $$c2018
000070325 5060_ $$aAccess copy available to the general public$$fUnrestricted
000070325 5203_ $$aElectrochemical ammonia sensors were used to analyse the existing relationship between the ammonia concentration and ambient levels of both temperature and relative humidity in commercial lamb fattening housing equipped with mechanical ventilation and straw-bedded pens. In the first stage of the experiment, sensors were placed over straw beds covered in lamb urine and analysed under laboratory conditions in order to determine ammonia emission evolution over time; three control temperatures (25, 35, and 50 degrees C) were used. A HOBO H8 temperature and relative humidity logger and a Drager NH3LC-6809680 electrochemical ammonia sensor placed in a Drager Polytron 7000 gas detector were utilized as sensors. A positive correlation was established between both ammonia emission time and emitted amount with temperature. Additionally, tests were performed in a commercial lamb housing to determine ammonia concentration variation with respect to height from the ground; three ammonia sensors placed at 50, 90, and 135 cm above the ground were used simultaneously. The ammonia concentration significantly decreased as height increased. A 90 cm height was selected, and three ammonia probes were placed in three different pens inside the livestock housing, along with temperature and relative humidity sensors; four different housing ventilation rates were then tested under real conditions over a time period of 4 months. An adjustment polynomial equation between the housing ambient temperature and the ammonia concentration was obtained with R-2 = 0.632. In conclusion, a relationship can be established between temperature and ammonia concentration in commercial lamb housing under certain handling conditions, which in turn allows for estimating the ammonia concentration adequately based on the ambient internal temperature.
000070325 540__ $$9info:eu-repo/semantics/openAccess$$aby$$uhttp://creativecommons.org/licenses/by/3.0/es/
000070325 590__ $$a2.024$$b2018
000070325 591__ $$aINSTRUMENTS & INSTRUMENTATION$$b30 / 61 = 0.492$$c2018$$dQ2$$eT2
000070325 591__ $$aENGINEERING, ELECTRICAL & ELECTRONIC$$b140 / 265 = 0.528$$c2018$$dQ3$$eT2
000070325 592__ $$a0.34$$b2018
000070325 593__ $$aControl and Systems Engineering$$c2018$$dQ2
000070325 593__ $$aInstrumentation$$c2018$$dQ2
000070325 593__ $$aElectrical and Electronic Engineering$$c2018$$dQ2
000070325 655_4 $$ainfo:eu-repo/semantics/article$$vinfo:eu-repo/semantics/publishedVersion
000070325 700__ $$aAguirre, A.J.
000070325 700__ $$aBarreiro, P.
000070325 700__ $$aHorcas, E.
000070325 700__ $$0(orcid)0000-0001-8526-351X$$aBone, A.$$uUniversidad de Zaragoza
000070325 700__ $$0(orcid)0000-0003-0373-8310$$aVidal, M.$$uUniversidad de Zaragoza
000070325 7102_ $$15011$$2500$$aUniversidad de Zaragoza$$bDpto. CC.Agrar.y Medio Natural$$cArea Ingeniería Agroforestal
000070325 7102_ $$15004$$2545$$aUniversidad de Zaragoza$$bDpto. Ingeniería Mecánica$$cÁrea Ingeniería Mecánica
000070325 7102_ $$15002$$2305$$aUniversidad de Zaragoza$$bDpto. Ingeniería Diseño Fabri.$$cÁrea Expresión Gráfica en Ing.
000070325 773__ $$g2018, 4032043  (2018), [8 pp]$$pJ. sens.$$tJournal of Sensors$$x1687-725X
000070325 8564_ $$s1561422$$uhttps://zaguan.unizar.es/record/70325/files/texto_completo.pdf$$yVersión publicada
000070325 8564_ $$s29380$$uhttps://zaguan.unizar.es/record/70325/files/texto_completo.jpg?subformat=icon$$xicon$$yVersión publicada
000070325 909CO $$ooai:zaguan.unizar.es:70325$$particulos$$pdriver
000070325 951__ $$a2020-06-09-13:22:02
000070325 980__ $$aARTICLE